DP955 is the latest innovation in roofing profiles. Designed not only to be stronger than traditional profiles but also more cost effective and faster to install. The new design provides stronger ribs to protect against buckling and a wide style pan to allow for safe foot placement. With a wider cover width of 955mm, fewer DP955 sheets are required to be installed, saving both time and money.DP955’s original look creates a distinctive and diverse design unlike traditional profiles ensuring a unique finish.


Cover:
955mm Sheet Width: 1020mm
Minimum Pitch 3° (approx 1:20)

 

ROOFING SPAN CAPACITY CHART
  CLADDING SPAN CAPACITY CHART
Thickness End Span Internal Span
0.40mm 1.60m 2.40m
0.55mm 2.70m 4.00m
 
Thickness End Span Internal Span
0.40mm 2.60m 3.00m
0.55mm 2.90m 4.30m
* To suit ultimate wind loads up to 3 kPa

Note: Spans shown above are for steel. When using other materials please call 0800 Dimond for more info.

All roofing spans shown are maximum spans to suit occasional foot traffic only. Not suitable for use as a platform for maintenance work.

TOP

For comprehensive information on Dimond systems which include CAD drawings, Installation documents and PDF downloads, use one of the following links below

Dimond Roofing & Cladding Systems Manual
Dimond Roofing & Cladding Systems Manual
Dimond Structural Systems Manual
Dimond Structural Systems Manual

Technical Documents
Documents Drawings Drawings
2.1.4.18. DP955 14


Download a lite version of the Roofing & Cladding Systems Manual (PDF - 1.4MB)

Download Roofing/Cladding installation Info (PDF - 560KB)

 
A Fletchers Building Company © Dimond, all rights reserved. Please read our Privacy Policy and Terms & Conditions.
Dimond is a member of the Roofing Association of New Zealand Roofing Association NZ

Powered by streamSWEET CMS